Thermostat-Klemme J4 3-polig (L/Ls/N), J3 nach rechts; Leistung = Strom x einstellbarem Faktor W/A statt fester cos phi 0,9
This commit is contained in:
1 parent
1301212f13
commit
a82b8dd58e
13 files changed
+22587
-23006
No files matched your search
@@ -109,6 +109,17 @@ servo:
|
||||
auto_detach_time: 3s # danach kein Haltestrom/Brummen; Klappe hält per Getriebe
|
||||
|
||||
number:
|
||||
- platform: template
|
||||
name: "Pumpe Faktor W pro A"
|
||||
id: pumpe_w_pro_a
|
||||
min_value: 50
|
||||
max_value: 230
|
||||
step: 1
|
||||
initial_value: 115
|
||||
optimistic: true
|
||||
restore_value: true
|
||||
entity_category: config
|
||||
icon: mdi:tune
|
||||
- platform: template
|
||||
name: "Luftklappe"
|
||||
id: luftklappe
|
||||
@@ -154,12 +165,14 @@ sensor:
|
||||
- multiply: 10.0 # V an 100 R -> A primär
|
||||
- lambda: 'return x < 0.015f ? 0.0f : x;'
|
||||
- platform: template
|
||||
name: "Pumpe Leistung (ca.)"
|
||||
name: "Pumpe Leistung (geschätzt)"
|
||||
unit_of_measurement: W
|
||||
device_class: power
|
||||
accuracy_decimals: 0
|
||||
update_interval: 5s
|
||||
lambda: 'return id(pumpe_strom).state * 230.0f * 0.9f;' # Schein -> grob Wirkleistung (cos phi ~0,9 schätzen)
|
||||
# Wirkleistung = Strom x Faktor (W/A). Faktor einmal mit Shelly einmessen: Shelly-Watt / "Pumpe Strom".
|
||||
# Ohne Einmessung 230 V x cos phi 0,5 (typisch für EC-Hocheffizienzpumpen ohne PFC).
|
||||
lambda: 'return id(pumpe_strom).state * id(pumpe_w_pro_a).state;'
|
||||
|
||||
- platform: max6675
|
||||
cs_pin: GPIO15 # D8 (10k Pull-down auf der Platine)
|
||||
|
||||
Reference in new issue